Lumens to Lux & LED Bulb Calculator

Work out how many lumens a room needs from its size and use, convert to lux and foot-candles, and count the LED bulbs or fixtures to buy.

Updated · Free · Runs in your browser

Units
ft
ft
%

Lower for dark walls, high ceilings or shaded fittings.

lm

A '60 W equivalent' LED gives about 800 lm.

lm/W
Bulbs or fixtures needed —
Lumens needed —
Target level —
Achieved —
Power —
Lumens per area —
Room area —
    Was this calculator helpful?

    The formula

    Lumens needed = target lux × floor area (m²) ÷ (utilisation factor × maintenance factor 0.8)
    Lux = lumens per m² reaching the surface · 1 foot-candle = 1 lumen per ft² = 10.764 lux
    Bulbs = ceil(lumens needed ÷ lumens per bulb)
    LED watts = lumens ÷ efficacy (lm/W)
    
    Typical targets: living room and bedroom 100–200 lux · kitchen and bathroom 300 · office and study 500 · workshop 750+

    Worked example

    1. A 14 × 12 ft kitchen (168 sq ft, 15.6 m²) needs about 300 lux.
    2. With 60% of light reaching the work surface and a 0.8 maintenance factor:
    3. Lumens = 300 × 15.6 ÷ (0.6 × 0.8) = 9,755 lumens.
    4. Using 800-lumen LED bulbs (the '60 W equivalent'): 9,755 ÷ 800 = 12.2, so 13 bulbs, delivering about 320 lux (30 foot-candles).
    5. At 100 lumens per watt, that's about 98 W of LEDs, compared with nearly 700 W of incandescent bulbs.

    Lumens, lux and foot-candles

    Lumens measure the total amount of visible light a bulb or fixture produces. Lux measures how much of that light falls on a surface: one lux is one lumen spread over one square metre. In the US, light levels are often given in foot-candles, one lumen per square foot, which equals 10.764 lux. A bulb's lumen rating stays the same wherever you put it, but the lux on your worktop depends on the room's size, the distance and direction of the light, and how much is absorbed by walls and shades.

    How much light each room needs

    Recommended levels come from lighting bodies such as the Illuminating Engineering Society (IES) in North America and the Society of Light and Lighting and EN 12464-1 in Europe. Typical values are about 100–200 lux for living rooms, bedrooms and hallways, 300 lux for kitchens and bathrooms, 500 lux for offices, studies and kitchen worktops, and 750–1,000 lux for workshops, sewing and other detailed tasks. Older people need more light: a 60-year-old needs roughly twice as much as a 20-year-old to see equally well. Layer ambient, task and accent lighting rather than relying on one bright source.

    Utilisation and maintenance factors

    Not all of a bulb's light reaches where you need it. Some is absorbed by lampshades, fittings and dark walls, or lands above the work surface. The utilisation factor accounts for this: around 60% is typical for a domestic room with light-coloured walls, less for dark décor, high ceilings or enclosed fittings, and more for small, bright rooms. The maintenance factor of 0.8 allows for light output falling as LEDs age and fixtures collect dust, so the room still has enough light later in the bulbs' life.

    Choosing LED bulbs

    Buy bulbs by lumens, not watts. As a guide, a 40 W-equivalent LED gives about 450 lumens, 60 W about 800, 75 W about 1,100 and 100 W about 1,600. Modern LEDs produce 80–150 lumens per watt, compared with about 14 for incandescent bulbs, so the same light uses roughly 85–90% less electricity. Also check colour temperature: 2,700–3,000 K (warm white) suits living spaces and bedrooms, 3,500–4,000 K (neutral) kitchens and bathrooms, and 5,000 K+ (daylight) workshops and garages. A colour rendering index (CRI) of 90 or more shows colours more accurately.

    Placing the lights

    Even distribution matters as much as total lumens. For recessed downlights, a common rule is to space them about half the ceiling height apart, so roughly 4 ft (1.2 m) apart with an 8 ft ceiling, and about half that distance from the walls. Put task lights such as under-cabinet strips directly over kitchen worktops, desks and benches to avoid shadows from your own body. Dimmers let one installation serve both bright tasks and relaxing evenings.

    Outdoor and security lighting

    Outdoor lighting needs far fewer lumens than people often assume. Path lights of 100–200 lumens, porch lights of 400–800 lumens and floodlights of 1,000–2,000 lumens are usually plenty. Overly bright, unshielded lights cause glare, light pollution and annoyance to neighbours. Choose fully shielded fittings that point down, warm colour temperatures of 3,000 K or below, and motion sensors or timers so lights are only on when needed.

    Running costs

    Lighting is cheap to run with LEDs. Thirteen 8 W LED bulbs on for 5 hours a day use about 190 kWh a year, roughly $28 at 15 cents per kWh. Work out the exact figure with our appliance electricity cost calculator. If you're redecorating at the same time, lighter wall colours from the paint calculator reflect more light and reduce the number of bulbs you need.

    Frequently asked questions

    How many lumens do I need per square foot?
    About 10–20 lumens per sq ft for living rooms and bedrooms, 30–40 for kitchens and bathrooms, and 50–80 for offices, workshops and task areas, before allowing for light losses.
    How do I convert lumens to lux?
    Divide the lumens reaching a surface by its area in square metres. 1,000 lumens spread evenly over 10 m² is 100 lux.
    How many lux is a foot-candle?
    One foot-candle equals 10.764 lux. 30 foot-candles is about 320 lux.
    How many lumens is a 60 W bulb?
    About 800 lumens. A 60 W-equivalent LED gives the same light while using only about 8–9 W.
    How many recessed lights do I need?
    Divide the room's lumen requirement by the lumens per fixture. As a spacing guide, place downlights about half the ceiling height apart.

    ↑↓ to navigate · Enter to open