Rain Gutter & Sump Pump Size Calculator

Size gutters and downspouts from roof area, pitch and rainfall intensity, or size a sump pump from the rate water fills your sump pit.

Updated · Free · Runs in your browser

Size a
Units
ft²

Footprint area, not sloped area.

in/h

5-minute peak; often 3–8 in/h in the US.

ft
Downspout size
Recommended size —
Peak runoff —
Pitch-adjusted roof area —
Downspouts —
Gutter capacity —
Measured inflow —
Typical pump size —
    Was this calculator helpful?

    The formula

    Gutters:
    Adjusted roof area = plan area × pitch factor (1.00 flat · 1.05 at 4–5/12 · 1.10 at 6–8/12 · 1.20 at 9–11/12 · 1.30 at 12/12+)
    Load = adjusted area × rainfall intensity (in/h)
    Capacity (level gutter): 5 in K-style ≈ 5,520 · 6 in ≈ 7,960 · 7 in ≈ 12,500 ft²·in/h
    Peak runoff (gpm) = area (ft²) × intensity (in/h) × 0.0104
    
    Sump pump:
    Inflow (gal/min) = π × (pit diameter ÷ 2)² × rise ÷ 231 ÷ minutes
    Pump capacity = inflow × 1.5 at total head = vertical lift + horizontal run ÷ 10

    Worked example

    1. A 1,200 sq ft roof section at 6/12 pitch drains to a 40 ft gutter, with a design rainfall of 4 in/h.
    2. Adjusted area = 1,200 × 1.10 = 1,320 sq ft, so the load is 1,320 × 4 = 5,280 sq ft·in/h.
    3. A 5 in K-style gutter (5,520) is just enough; peak runoff is about 55 gpm.
    4. With 2 × 3 in downspouts, plan for 3 of them.
    5. For a sump pump: water rose 4 in in an 18 in pit in 60 seconds, so inflow = π × 9² × 4 ÷ 231 = 4.4 gpm.
    6. With a 50% margin, the pump should move about 7 gpm against 10 ft of lift + 20 ft of pipe ÷ 10 = 12 ft of head: a ⅓ hp pump is ample.

    Sizing gutters

    A gutter must carry the rain falling on the roof area that drains to it during the heaviest likely downpour. Two things matter: the roof area and the rainfall intensity. Steeper roofs catch more wind-driven rain, so the roof's plan area is increased by a pitch factor, following the approach in the SMACNA Architectural Sheet Metal Manual. Rainfall intensity is the peak rate over a short period, often five minutes, for a chosen return period. In much of the US it ranges from about 3 in/h in the Pacific Northwest to 8 in/h or more along the Gulf Coast. UK practice under BS EN 12056-3 often uses 75 mm/h for houses.

    Gutter types and capacity

    The 5 in K-style gutter is the most common size on American homes, and 6 in gutters suit larger or steeper roofs and heavy-rain regions. K-style gutters hold more water than half-round gutters of the same width. Capacity also depends on the gutter's slope and the number and position of downspouts: a gutter that drains in both directions to two outlets carries far more than one that drains to a single end outlet. In the UK and Europe, common sizes are 112–125 mm half-round and 115–150 mm square or ogee profiles, with 68 mm round or 65 mm square downpipes.

    Downspouts

    As a rule of thumb, allow at least one square inch of downspout opening for every 100 square feet of roof: a 2 × 3 in downspout serves up to about 600 sq ft and a 3 × 4 in downspout about 1,200 sq ft. Place one at least every 30–40 ft of gutter and near the corners of the roof. Downspouts should discharge at least 4–6 ft (1.2–1.8 m) from the foundation, using extensions, splash blocks or underground drains, so water doesn't soak into the soil around the basement.

    Sizing a sump pump

    The best way to size a sump pump is to measure how fast water enters the pit during heavy rain or snowmelt. Turn the pump off briefly or wait until it has just cycled, measure how many inches the water rises in one minute, and enter the pit diameter. The calculator converts that rise into gallons or litres per minute and adds a 50% safety margin. A pump also has to push water up and out of the house, so total head includes the vertical lift from the pit to the discharge point plus an allowance for friction in horizontal pipe, roughly 1 ft of head for every 10 ft of pipe.

    Choosing a pump

    Pump performance is shown on a curve of flow against head. Choose a model that delivers at least the required flow at your total head. Most homes are well served by a ⅓ or ½ hp submersible pump; ¾ to 1 hp suits high water tables or tall lifts. Cast-iron submersible pumps last longer than plastic ones, and a vertical float switch is more reliable than a tethered float in narrow pits. A battery backup pump or water-powered backup is good insurance against power cuts during storms, which is exactly when flooding is most likely. Check pump and discharge pipe sizes with our pipe friction loss calculator.

    Maintenance

    Clean gutters at least twice a year, more often under trees, and consider gutter guards. Overflowing gutters can cause fascia rot, damp walls and basement leaks. Test sump pumps every few months by pouring water into the pit until the float lifts, and check that the discharge line is clear and, in cold climates, protected from freezing. For larger site drainage, culverts and ditches, use the Manning's equation calculator, and for roof areas the roofing calculator.

    Frequently asked questions

    What size gutter do I need?
    For most homes, a 5 in K-style gutter is enough. Use 6 in gutters for large roof areas, steep roofs or regions with heavy rainfall, such as roof sections over about 1,300 sq ft at 4 in/h.
    How many downspouts do I need?
    At least one for every 30–40 ft of gutter, and enough opening area for the roof: about 600 sq ft per 2 × 3 in downspout and 1,200 sq ft per 3 × 4 in downspout.
    How do I calculate sump pump size?
    Measure how fast water rises in the pit, convert to gallons per minute, add a safety margin and choose a pump that delivers that flow at your total head (vertical lift plus about 1 ft per 10 ft of horizontal pipe).
    Is a ⅓ hp sump pump enough?
    For most homes with modest inflow and a lift of up to about 10 ft, yes. Choose ½ hp or more for high water tables, heavy inflow or lifts above 10–15 ft.
    How much water comes off a roof?
    About 0.62 US gallons per square foot for every inch of rain. A 1,500 sq ft roof sheds roughly 935 gallons from 1 in of rain.

    ↑↓ to navigate · Enter to open