    The formula

    Bars along the length = floor((width − 2 × cover) ÷ spacing) + 1
    Bars across = floor((length − 2 × cover) ÷ spacing) + 1
    Bar run length = slab dimension − 2 × cover (+ laps where runs exceed one stock bar)
    Lap = lap factor × bar diameter (often 40d)
    Total length = Σ bar runs × layers
    Stock bars = ceil(total length × 1.05 ÷ stock length)
    Weight per unit length = 7,850 kg/m³ × π × d² ÷ 4  (#4 = 0.668 lb/ft; 12 mm = 0.888 kg/m)

    Worked example

    1. A 20 × 20 ft slab is reinforced with #4 bars at 12 in centres each way, with 3 in edge cover.
    2. The bars run 20 ft − 2 × 3 in = 19.5 ft, so each one fits in a single 20 ft stock bar with no laps.
    3. Bars each way = floor(19.5 ÷ 1) + 1 = 20, so 40 bars in total.
    4. Total length = 40 × 19.5 = 780 ft.
    5. Weight = 780 × 0.668 lb/ft = 521 lb.
    6. With 5% for waste, order 780 × 1.05 ÷ 20 = 40.95, or 41 stock bars ($492 at $12 each).

    Why concrete needs reinforcement

    Concrete is very strong in compression but weak in tension, typically only about a tenth as strong. Without reinforcement it cracks when it bends, shrinks or settles. Steel reinforcing bar (rebar) carries the tensile forces and holds cracks tightly closed, so the slab or wall stays intact. Slabs on the ground are often reinforced with a single mat of bars or welded wire mesh near the middle or upper third, while suspended slabs, footings, beams and retaining walls are designed by an engineer, who specifies bar sizes, spacing, cover and laps.

    Bar sizes

    In the US, rebar is identified by a number equal to its diameter in eighths of an inch: #3 is ⅜ in, #4 is ½ in and #5 is ⅝ in. Common residential sizes are #3 and #4 for slabs and #4 and #5 for footings. Their weights are 0.376, 0.668 and 1.043 lb per foot. Elsewhere, rebar is sized by its diameter in millimetres: 8, 10, 12, 16, 20 and 25 mm are standard, weighing about d²/162 kg per metre (0.617 kg/m for 10 mm, 0.888 kg/m for 12 mm). Rebar is sold in stock lengths of 20 ft or 40 ft in the US, and 6 m or 12 m in most other countries.

    Spacing and cover

    Typical spacing for residential slabs is 12–18 in (300–450 mm) each way, and closer for heavier loads. Concrete cover, the thickness of concrete between the steel and the surface, protects the bars from corrosion and fire. The American Concrete Institute's ACI 318 code requires 3 in for concrete cast against the ground, 1½–2 in for concrete exposed to weather, and ¾ in for interior slabs not exposed to weather. In the UK and Europe, Eurocode 2 specifies cover by exposure class, typically 25–50 mm, plus allowances. Support bars on chairs or spacers so they stay at the right height while the concrete is placed; bars lying on the ground do nothing.

    Laps and splices

    Where a run is longer than one stock bar, two bars are overlapped and tied together so force can transfer between them. The lap length is usually expressed as a multiple of the bar diameter, often 40 to 60 diameters depending on the bar grade, concrete strength and position. A #4 bar with a 40d lap needs 20 in of overlap. The calculator adds laps automatically for runs longer than the stock length. Stagger laps so they don't all fall in the same place, and follow your engineer's lap schedule for structural work.

    Welded wire mesh and fibres

    For lightly loaded slabs, such as patios, sheds and some garage floors, welded wire reinforcement (mesh) is a common alternative to loose bars. In the US, 6 × 6 W1.4 × W1.4 mesh is typical for residential slabs; in the UK, A142 and A193 mesh sheets are widely used. Synthetic or steel fibres mixed into the concrete reduce plastic shrinkage cracking but don't replace structural reinforcement unless designed to. Whatever you use, it must sit within the concrete, usually in the upper third of a ground slab, not on the ground.

    Ordering and handling

    Order a little extra, typically 5–10%, for cutting waste and mistakes. Tie intersections with wire at least every other crossing, and put plastic caps on exposed bar ends for safety. Rebar is often sold per bar or by weight (per ton or per tonne). Use our concrete calculator to work out how much concrete the slab needs, and the brick and block calculator for reinforced block walls.

    Frequently asked questions

    How much does rebar weigh?
    #3: 0.376 lb/ft; #4: 0.668 lb/ft; #5: 1.043 lb/ft; #6: 1.502 lb/ft. In metric, 10 mm weighs 0.617 kg/m, 12 mm 0.888 kg/m and 16 mm 1.58 kg/m.
    What size rebar is used for a slab?
    #3 or #4 bars (10–12 mm) at 12–18 in centres for most residential slabs on the ground. Engineers may specify more for heavy loads or poor soils.
    How far apart should rebar be?
    Usually 12–18 in (300–450 mm) on centre each way for slabs. Codes limit the maximum spacing, typically to 18 in or three times the slab thickness.
    How much should rebar overlap?
    Often 40 to 60 bar diameters, as specified by the engineer. For #4 (½ in) bars, a 40d lap is 20 in.
    How much concrete cover does rebar need?
    3 in (75 mm) when cast against the ground, 1½–2 in for concrete exposed to weather, and ¾ in for protected interior slabs, under ACI 318.