Water Heater Size Calculator (Tank & Tankless)

Find the first-hour rating and tank size your household needs, or the flow rate and power a tankless water heater must deliver.

Updated · Free · Runs in your browser

Units
min
gpm

Federal maximum 2.5 gpm; WaterSense heads 2.0 or less.

°F
°F

About 40 °F in northern US winters, 70 °F in the south.

Recommended tank size —
First-hour demand —
Tankless flow needed —
Tankless power needed —
Electric tankless current —
    Was this calculator helpful?

    The formula

    Tank (first-hour demand, US DOE method):
    Shower hot water ≈ minutes × flow × 0.7 · bath 20 gal · dishwasher 6 gal · clothes washer 7 gal · kitchen or basin 2 gal
    Choose a tank whose first-hour rating (FHR) ≥ peak-hour demand
    
    Tankless:
    Flow = simultaneous showers × shower flow + other fixtures × 1.5 gpm
    Temperature rise = hot water setpoint − incoming water temperature
    Gas input (BTU/h) = gpm × 500 × rise (°F) · Electric kW = BTU/h ÷ 3,412

    Worked example

    1. In the busiest morning hour, a household takes three 10-minute showers at 2.0 gpm, runs the dishwasher and uses the kitchen sink twice.
    2. Showers: 3 × 10 × 2.0 × 0.7 = 42 gal of hot water. Add 6 for the dishwasher and 2 × 2 for the sink: 52 gal.
    3. A 40 gal gas tank with a first-hour rating of about 67 gal covers this comfortably.
    4. For a tankless heater supplying two showers and one tap at once: 2 × 2.0 + 1.5 = 5.5 gpm.
    5. Raising 50 °F water to 120 °F (a 70 °F rise) needs 5.5 × 500 × 70 = 192,500 BTU/h of gas, or 56 kW electric.

    Tank sizes and first-hour rating

    A tank water heater's most useful number isn't its capacity but its first-hour rating (FHR): how many gallons of hot water it can supply in an hour starting with a full tank. FHR combines the stored water, most but not all of which is usable before it cools, with how quickly the burner or elements reheat water. Gas heaters reheat faster than electric ones, so a 40 gal gas tank often has an FHR of 65–75 gal, while a 50 gal electric tank may be around 60. In the US, FHR is on the yellow EnergyGuide label. Size your heater by working out how much hot water you use in your busiest hour.

    Estimating peak-hour use

    The US Department of Energy suggests these typical hot-water amounts: a shower 10 gal, a bath 20 gal, shaving 2, hand dishwashing 4, an automatic dishwasher 6, food preparation 5 and a clothes washer 7. Showers vary the most, so the calculator works them out from length and flow rate, assuming about 70% of shower water is hot at a comfortable temperature. As a rough guide by household size: 1–2 people often need 30–40 gal tanks, 2–4 people 40–50 gal, and 5 or more 50–80 gal, or two heaters.

    Sizing a tankless heater

    A tankless (on-demand) heater heats water as it flows, so it never runs out, but it has a maximum flow rate at any given temperature rise. You size it by how many fixtures run at the same time and how much the water must be heated. Incoming water is colder in winter and in northern regions, often 40–45 °F (5–7 °C), than in southern areas, where it may be 65–75 °F (18–24 °C). A typical whole-house gas tankless unit of 180,000–199,000 BTU/h delivers about 5–6 gpm at a 70 °F rise. Electric tankless heaters for whole houses need very large electrical supplies, often 120–160 A or more at 240 V, which many homes can't support without an upgrade.

    Metric and European systems

    In the UK, Europe, Australia and India, hot water is often stored in unvented cylinders or heated by combination (combi) boilers, which work like tankless heaters. Combi boilers are rated by kW: a 24 kW combi delivers about 10 L/min at a 35 °C rise, enough for one shower, while 30–35 kW models support a shower and a tap together. Cylinders of 150–210 litres suit most family homes. Heat pump water heaters are increasingly popular everywhere and can cut water-heating energy by two-thirds.

    Energy, safety and running costs

    Water heating is often the second-largest energy use in a home after space heating. A setpoint of 120 °F (49 °C) is recommended in the US to reduce scalding risk and energy use, while UK and EU guidance is to store water at 60 °C to control Legionella bacteria, with thermostatic mixing valves at taps. Insulating hot-water pipes, fixing drips and fitting low-flow showerheads all reduce the size of heater you need and lower bills. Compare running costs with our electricity cost calculator, and check pipe sizes and pressure loss with the pipe friction loss calculator.

    Signs your heater is too small

    If hot water regularly runs out during morning showers, the water gets lukewarm when two people use it at once, or the heater runs almost constantly, it's probably undersized. Sediment build-up in older tanks also reduces capacity and efficiency, so flush tanks once a year. When replacing a heater, consider your household's likely needs over the next 10–15 years, as tanks typically last 8–12 years and tankless units up to 20.

    Frequently asked questions

    What size water heater do I need for a family of four?
    Typically a 40–50 gal gas tank or a 50–65 gal electric tank, depending on your busiest-hour demand. Check the first-hour rating rather than just the tank size.
    What is a first-hour rating?
    The number of gallons of hot water a tank heater can deliver in one hour starting with a full tank. Choose one at least equal to your busiest-hour hot water use.
    How many gpm do I need for a tankless water heater?
    Add up the fixtures likely to run at once: about 2 gpm per shower, 1–1.5 gpm per tap and 1.5–2 gpm for a washer or dishwasher. Most homes need 5–8 gpm.
    Why does a tankless heater deliver less in winter?
    Incoming water is colder, so the heater must raise its temperature more. The same burner can only heat less water per minute when the temperature rise is larger.
    What temperature should a water heater be set to?
    120 °F (49 °C) is recommended in the US to prevent scalding. UK and EU guidance is to store hot water at 60 °C to prevent Legionella, with mixing valves at taps.

    ↑↓ to navigate · Enter to open